What Each Test Actually Measures: F1869 vs. F2170 at a Glance

ASTM F1869 measures moisture vapor emission rate (MVER) at the slab surface using calcium chloride, while ASTM F2170 measures relative humidity (RH) inside the concrete at a depth tied to slab thickness. Both are active, current ASTM standards. Neither has been withdrawn or replaced by the other.

We get this question constantly from GCs and facility owners who assume one test has quietly retired the other. It hasn’t happened, and ASTM hasn’t signaled that it will. What has happened is a shift in specifier preference, driven by what each test can and cannot see inside a slab. F1869 tells you how much moisture is leaving the top quarter-inch of concrete at the moment of testing. F2170 tells you the humidity condition at a depth representative of the slab’s future drying behavior, typically 40% of slab depth for slabs drying from one side. That difference in depth is the whole story, and it’s why the rest of this article exists.

Attribute ASTM F1869 (Calcium Chloride) ASTM F2170 (In-Situ RH)
What it measures Moisture vapor emission rate at surface Relative humidity inside slab at depth
Units Lbs per 1,000 sq ft per 24 hrs % relative humidity
Sensing depth Top ~1/4 inch of slab Typically 40% of slab depth (one-side drying)
Test duration 60-72 hours Probes equilibrate 24 hrs minimum, read in place
Sensitivity to ambient conditions High, requires tight temp/RH control Lower, measures inside the slab mass
Predicts long-term drying trend Limited Better correlated to long-term slab moisture behavior

Inside ASTM F1869: How the Calcium Chloride Test Works

ASTM F1869 covers the quantitative determination of moisture vapor emitted from below-grade, on-grade, and above-grade bare concrete floors. The current 2023 edition (with prior active editions in 2022 and 2016a) confirms this is a maintained, current standard, not a deprecated one, per ASTM International.

The procedure itself hasn’t changed much in decades, which is part of its appeal to contractors who want something simple and repeatable. A dish of anhydrous calcium chloride is weighed, placed on a prepared area of bare concrete, and sealed under an airtight dome. After 60 to 72 hours, the dish is weighed again. The weight gain, converted through a standard calculation, yields the moisture vapor emission rate in pounds of moisture per 1,000 square feet per 24 hours (ASTM International, ASTM F1869, 2023; also documented by Tool Experts, 2025).

Manufacturers commonly flag anything exceeding roughly 3 lbs per 1,000 sq ft per 24 hours as a failure threshold for moisture-sensitive flooring systems, though the actual limit depends on the flooring adhesive or system spec (AMPP, “Concrete Moisture Testing and Mitigation”).

Test prep matters more than most crews realize. ASTM F1869 calls for a clean 20 in. by 20 in. bare concrete test area with all coatings, adhesives, and surface contaminants removed, then a mandatory 24-hour wait before placing the kit so any residual surface moisture from grinding or cleaning can equilibrate (Tool Experts, “ASTM F1869 Calcium Chloride Moisture Test Kit,” 2025). Skip that wait and the reading is compromised before the dish ever goes down.

Ambient conditions are just as strict. The standard requires the space be held at 65-75°F and 40-60% relative humidity for at least 48 hours before testing and throughout the test window (Tool Experts, 2025). Testing frequency follows a set ratio: three tests for the first 1,000 sq ft of floor area, then one additional test for every 1,000 sq ft after that. On a 50,000 sq ft distribution center floor, that’s roughly 52 individual test locations, each with its own dish, dome, and 60-plus-hour dwell time.

Inside ASTM F2170: How In-Situ RH Testing Works

ASTM F2170 measures the relative humidity of air inside a hole drilled into the concrete slab, using a probe or sensor sleeve positioned at a depth calculated from the slab’s total thickness and drying condition. It captures the internal moisture state of the concrete mass rather than surface behavior alone.

The mechanics differ from F1869 in almost every respect. Instead of measuring what’s leaving the surface, F2170 drills into the slab (typically to 40% of slab depth for slabs drying from the top only, or 20% for slabs drying from both sides) and inserts a sensor sleeve. The hole is sealed and the probe is left to equilibrate, usually a minimum of 24 hours, before a reading is taken. What comes back is a straightforward percentage: 75% RH, 85% RH, and so on, reflecting the humidity of the air trapped at that depth inside the concrete.

Because the sensor sits below the zone most affected by ambient room air, temporary HVAC swings, or a recent rainstorm hitting an unenclosed building, the reading is less volatile and more representative of where the slab’s moisture condition is actually heading. That’s the core engineering advantage over a surface-only test, and it’s the reason F2170 results are used to predict long-term flooring performance rather than just a snapshot at the moment of testing.

Why the Industry Shifted Toward RH Testing

Flooring manufacturers and adhesive makers increasingly write ASTM F2170 compliance into their installation and warranty requirements because RH testing better predicts how a slab will behave over the life of the floor, not just at handoff. Failing to test per the manufacturer’s specified method can void a flooring warranty regardless of which test result looked acceptable.

This shift isn’t about F1869 being wrong. It’s about what a warranty department is actually trying to de-risk. A calcium chloride reading taken on install day tells you almost nothing about whether that slab will still be dry enough in year three, after the HVAC gets turned off over a long weekend, after a loading dock door gets left open through a humid August, or after robotics traffic changes the thermal profile of the floor. RH testing, because it reads the internal condition of the concrete mass, correlates more reliably with the slab’s ongoing drying trajectory. Manufacturers that have paid out warranty claims on adhesive failure and cupping know which test gave them better advance warning, and their current installation guides reflect that lesson.

Specifiers on high-value builds have followed suit. If you’re bidding a flooring package for a healthcare facility, a cold-storage distribution center, or a high-bay warehouse with automated storage and retrieval systems, expect the architect’s or owner’s moisture spec to name F2170, sometimes alongside F1869 as a secondary check, rather than F1869 alone.

The Real Limitation of Calcium Chloride: Surface Bias

The core technical limitation of ASTM F1869 is that it only senses moisture behavior in roughly the top quarter-inch of the slab. On thick commercial slabs, that shallow sampling depth can miss internal moisture that has not yet reached the surface but will migrate upward after flooring is installed and the slab is sealed.

This is the honest, standards-based case against relying on CaCl alone, and it has nothing to do with the test being poorly designed. It was engineered for a different question than the one commercial slab owners are asking today. A slab that reads acceptable on a Tuesday morning CaCl test can still have a moisture gradient deeper in the mass, one that hasn’t worked its way to the surface yet simply because concrete dries slowly and unevenly from the inside out. Once flooring, adhesive, or a vapor-retarding coating goes down on top, that surface layer is sealed, and the moisture trapped below has nowhere to go but up into the flooring system over the following months.

Ambient sensitivity compounds the problem. Because F1869 requires such tightly controlled temperature and humidity conditions (65-75°F, 40-60% RH) during the test window, a reading taken under conditions that drift even slightly outside that band can produce a result that doesn’t hold up once the building returns to normal operating conditions. On a job site where permanent HVAC isn’t yet running, that’s a real risk, not a theoretical one.

The risk on high-value slabs: a passing CaCl reading does not rule out elevated internal moisture deeper in the slab. On mission-critical floors, an F2170 result should confirm what a surface test alone cannot see.

When CaCl Still Makes Sense in 2026

ASTM F1869 remains a legitimate, cost-effective option for lower-risk applications: thin slabs, smaller tenant fit-outs, non-mission-critical spaces, and projects where the flooring manufacturer’s warranty explicitly accepts it. It also works well as a supplementary check alongside F2170 rather than a replacement for it.

There’s no reason to abandon CaCl testing on every project. On a retail buildout going over a slab that’s been in service for years and shows no history of moisture issues, or on a light-commercial office slab with standard VCT going down, a CaCl test that meets the manufacturer’s threshold is often sufficient and defensible. It’s also useful as a fast, low-cost screening tool early in a project, giving you a directional read before committing to the drilling, probe cost, and 24-hour-plus equilibration time that F2170 requires.

Some manufacturers still list CaCl as an accepted method in their installation guides for specific product lines, and following that guide exactly, including test area prep, ambient conditions, and spacing, is what protects your warranty claim if a dispute ever arises.

Where CaCl earns real skepticism is when it’s used alone, on a thick slab, for a flooring or coating system that’s sensitive to moisture, in a building without permanent climate control at the time of testing. That combination of factors is exactly where the surface-bias limitation described above turns into a callback, a delamination claim, or a re-pour.

When RH Testing Should Be the Primary Method

ASTM F2170 should be the primary or sole moisture test on slabs supporting high-bay racking, robotics or AMR traffic, healthcare flooring, distribution center operations, or any application where the flooring manufacturer’s warranty specifically requires it. These are the projects where a missed moisture problem is expensive to fix after the fact.

Think about what’s actually at stake on these floor types. A distribution center with automated guided vehicles running fixed routes doesn’t tolerate flooring failure the way a retail space might; downtime to rip up and replace a section of resin flooring under active racking is a logistics problem, not just a maintenance ticket. Healthcare facilities have infection-control and downtime constraints that make an unplanned flooring failure a much bigger event than the cost of the flooring itself. In all of these cases, the extra lead time F2170 requires (drilling, sleeve placement, minimum 24-hour equilibration before reading) is a rounding error against the cost of getting the moisture call wrong.

If your project falls into one of these categories and the spec still only names calcium chloride, that’s worth raising with the architect or owner’s rep before slab prep locks in a testing plan that can’t be walked back once flooring is installed. It’s a lot cheaper to add probe locations to next week’s schedule than to explain a flooring failure eighteen months from now.

Best Practice: Documentation, Combined Testing, and Protecting Your Warranty

Protecting a flooring warranty and avoiding disputes comes down to following the governing ASTM standard exactly, documenting test locations, dates, ambient conditions, and results in writing, and matching your test method to what the flooring manufacturer’s installation guide actually requires, not just what’s fastest or cheapest to run.

On mixed-risk projects, many specifiers now call for both tests: F1869 as a quick surface screen early in the schedule, F2170 at the depth-appropriate location as the test of record before flooring goes down. That combination gives you a paper trail showing due diligence at two different depths of the slab, which matters if a moisture-related claim surfaces two years into occupancy and someone starts asking who tested what, when, and how.

Documentation should include the exact test locations mapped to the floor plan, ambient temperature and humidity logs for the required equilibration window, the calibration status of the equipment used, and photos of test area prep. None of that is optional if you want the data to hold up in a warranty dispute or an insurance claim.

Moisture testing doesn’t happen in isolation from the rest of the slab’s quality profile. A slab can pass every moisture threshold and still be out of tolerance on flatness and levelness (ASTM E1155), which is its own risk to racking, AMR travel, and flooring longevity. Comprehensive slab evaluation on a high-bay or robotics floor typically checks both moisture and FF/FL numbers before anyone signs off on flooring installation.

Not sure which moisture test, or combination of tests, fits your slab’s risk profile?

Get a Free Consultation

Frequently Asked Questions

Has ASTM F1869 been discontinued or replaced by ASTM F2170?

No. ASTM F1869 is an active, maintained standard, currently in its 2023 edition, and has not been withdrawn or officially replaced. ASTM F2170 is a separate standard that measures a different property (internal relative humidity rather than surface vapor emission) and has become the preferred method for many manufacturers, but both standards remain in force.

What is the main technical difference between F1869 and F2170?

ASTM F1869 measures moisture vapor emission rate at the concrete surface, sensing roughly the top quarter-inch of the slab. ASTM F2170 measures relative humidity inside the slab at a depth based on slab thickness and drying condition, typically 40% of depth for one-sided drying. F2170 reflects internal moisture behavior; F1869 reflects surface-level emission at the time of testing.

Why do flooring manufacturers increasingly require F2170 testing?

Manufacturers require F2170 because internal relative humidity correlates more reliably with long-term slab drying behavior and flooring performance than a surface emission reading. Warranty claims tied to adhesive failure and moisture-related flooring problems have led many manufacturers to specify F2170 compliance as a condition of warranty coverage.

Can I still use calcium chloride testing on a commercial project in 2026?

Yes, calcium chloride testing per ASTM F1869 remains valid where the flooring manufacturer’s installation guide accepts it, typically for lower-risk applications such as thin slabs or standard commercial flooring systems. It is not recommended as the sole test on thick slabs supporting high-bay racking, robotics, healthcare, or other mission-critical flooring systems.

What happens if I rely only on a calcium chloride test and the slab still has moisture problems later?

Because F1869 only senses the top portion of the slab, it can miss internal moisture that has not yet migrated to the surface. That moisture can move upward after flooring is installed, contributing to adhesive failure, cupping, or delamination. Relying solely on CaCl on a high-risk slab may also fall outside the flooring manufacturer’s warranty requirements.

How long does an ASTM F2170 test take compared to F1869?

ASTM F1869 requires a 60 to 72 hour test window per location after a 24-hour surface equilibration wait. ASTM F2170 requires a minimum 24-hour equilibration period after the probe is installed before a reading is taken. Both require adequate lead time in the construction schedule before flooring installation begins.

Should moisture testing be done alongside floor flatness testing?

Moisture testing (ASTM F1869 or F2170) and floor flatness/levelness testing (ASTM E1155) evaluate different slab properties and are often performed together as part of a comprehensive slab quality assessment, particularly for high-bay racking or robotics floors where both moisture and flatness affect long-term performance.

Sources

  • ASTM International, “ASTM F1869: Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride” (2023 edition; prior active editions 2022, 2016a)
  • ASTM International, “ASTM F2170: Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes”
  • AMPP, “Concrete Moisture Testing and Mitigation”
  • Tool Experts, “ASTM F1869 Calcium Chloride Moisture Test Kit” (2025)
  • IFTI, “ASTM F2170 vs F1869: Which Concrete Moisture Test Is Right?” (2025)

This article is for general informational purposes only and does not constitute engineering, legal, or product-specific advice. Flatness and levelness requirements and results vary by project, specification, and site conditions. Consult IFTI and refer to current ASTM (e.g., E1155, F1869, F2170) and ACI standards for project-specific guidance.